Clean Room Monitor and Real Time Data Logger – THP-3002
₹9,975 – ₹15,225
Prices are inclusive of Delivery Charges.
THP-3002-SSC & THP-3002-SSW – (T + RH) or (T + DP) or (RH + DP) Indicator Transmitter – 1” display with built in real time data storage.
Libratherm offers Clean Room Monitoring System THP-3002, micro-controller-based Temperature, Humidity, Differential Pressure Indicator cum Transmitter with 1” high digital display for long-distance visibility and 4-20mA retransmission outputs for T, Rh and DP each. Real-time clock and calendar are visible on demand through keyboard selection. These instruments are specially designed for monitoring and real-time data logging of cleanroom environmental conditions. Models are also available without a data logging facility i.e. without a real-time clock and built-in memory.
Digital interfaces such as RS-485 or Ethernet are integrated with the hardware to communicate with PC or PLC or HMI. All three types of indicators have built-in memory and a real-time clock to store the T+RH+DP values at regular and programmable time intervals. The stored data can be downloaded onto the computer via RS485 or LAN connection. Libratherm offers Windows-based PC software to monitor and store the data in a continuous or batch format for online or offline viewing and analysis in tabular or graphical format. The software allows users to prepare the batch report with desired fields such as product name, batch name, customer name, etc. The THP series has built-in flash memory to store real-time 20000 + records.
Respective sensors for T, RH, and DP are built-in to the same indicator, or alternately provision for external sensor/transmitter is available.
This Pressure Monitoring System is housed in an elegant SS enclosure with a depth of just 30mm and hence can be easily concealed inside the PUF panels of the clean rooms. The front facia has slanted borders to prevent dust accumulation. All input and output cable connections are accessible from the top surface and DP connections are available through suitable nozzles on the bottom.
Key Features:
- Microcontroller based design.
- Elegant appearance, easy to operate and compact in size.
- Highly accurate and sturdy in operation.
- Three colour 1” display for simultaneous indication of T, Rh and DP.
- Ready for both analog and digital data transmissions.
- Built in memory and RTC for real time data storage.
- Stainless Steel (SS) enclosure – wall mount and flush mount.
- RS485 interface for BMS.
Technical Specifications
Parameters | Description |
---|---|
Sensors | External / Internal Capacitive / Pt-100 based T + Rh sensor and built in DP sensor. |
Temperature Range | -40.0 to 60.0 °C /-40.0 to 140.0 °F (any other desired range can be specified) |
Temperature Accuracy | +/- 0.3 °C/ °F |
%RH Range | 0.0 to 100.0 %RH |
RH Accuracy | +/-1.0 %RH @ 25.0 °C or +/-3.0%RH subject to type of sensor used. |
Diff. Pressure Range | +/-100 mmWC or +/-999 Pascal (UOM can be selected) |
DP connection using 6 mm self- lockable PU tube connector at the back. | |
DP Accuracy | +/- 1% of the calibrated range. |
Display of Parameter | 4 digits LED display each for T, %RH and DP – 1" height red /green/blue |
Display of Time /Calander | On demand through keyboard selection for Time in HH MM format and for Calendar in DD MM YY format. |
Power Requirement | 18 to 36 VDC (Typical 24VDC) @ 300mA (+/-10%) or 230VAC (Any one – user to specify) – using separate AC/DC adapter. |
Output 1 for Temperature | 4-20mA proportional to -40.0 to 60.0 °C (programmable range) |
Output 2 for % RH | 4-20mA proportional to 0.0 to 100.0 %RH |
Output 3 for DP | 4-20mA proportional to +/-100mmWC or +/-999 Pascal. |
High and Low Alarms | High and Low alarm set points for each parameter are user programmable. In case of deviation from the set value, the front panel LED lights and Beeper sounds (with snooze facility). |
Serial Output | Isolated 2 wire RS485 MODBUS RTU - with programmable SLAVE ID |
Ethernet Port | Ethernet port on RJ-45 jack with TCP/IP protocol. |
Built in Memory and RTC | Real time Data storage capacity of 20,000 records in 256KB of flash memory with built in RTC. |
Key board | Membrane key board is provided for programming real time, alarm values, MODBUS address and for calibration. |
SSC - Enclosure (Size) | (250w x 200h x 50d) mm. - Depth of max. 20mm front from Wall surface. |
SSW - Enclosure (Size) | (250w x 200h x 60d) mm. - Depth of max. 60mm front from Wall surface. |
Mounting | Concealed flush mounting on the PUF panel or on the wall surface. |
Ordering Information
Model | Specifications | Part no. |
---|---|---|
THP-3002-SSC | T+RH Indicator in SS concealed enclosure w/o Analog or Digital Interface | 1902-1-1 |
THP-3002-SSC | T+RH Indicator in SS concealed enclosure with Analog Interface of 2 x 4-20mA | 1902-1-2 |
THP-3002-SSC | T+RH Indicator with 2 x 4-20mA retransmission output in SS concealed enclosure + RTC + Built in Data storage memory | 1902-1-3 |
THP-3002-SSC | T+RH Indicator with RS485 serial interface in SS concealed enclosure + RTC + Built in Data storage memory | 1902-1-4 |
THP-3002-SSC | T+RH Indicator with Ethernet (RJ45) interface in SS concealed enclosure + RTC + Built in Data storage memory | 1902-1-5 |
THP-3002-SSW | T+RH Indicator in SS wall mount enclosure w/o Analog or Digital Interface | 1905-1-1 |
THP-3002-SSW | T+RH Indicator in SS wall mount enclosure with Analog Interface of 2 x 4-20mA | 1905-1-2 |
THP-3002-SSW | T+RH Indicator with 2 x 4-20mA retransmission output in SS wall mount enclosure + RTC + Built in Data storage memory | 1905-1-3 |
THP-3002-SSW | T+RH Indicator with RS485 serial interface in SS wall mount enclosure + RTC + Built in Data storage memory | 1905-1-4 |
THP-3002-SSW | T+RH Indicator with Ethernet (RJ45) interface in SS wall mount enclosure + RTC + Built in Data storage memory | 1905-1-5 |
Note: The T+RH sensor / transmitter will be external and DP sensor will be internal. Alternatively all 3 sensor/transmitter can be external. |
Related products
-
Clean Room Monitoring System – THP-302
₹8,033 – ₹9,450Select optionsAdd to WishlistAdd to Wishlist -
Clean Room Monitor and Real Time Data Logger – THP-3001
₹8,925 – ₹14,175Select optionsAdd to WishlistAdd to Wishlist -
Humidity Transmitter – Duct Mount (Dual Output) – HHX-440-DM
₹4,988Select optionsAdd to WishlistAdd to Wishlist