Master Slave Ramp Soak PID Temperature Controller – PRC-489
₹11,550 – ₹13,125
Prices are inclusive of Delivery Charges.
PRC-489 – Single input, Single profile of 16 steps Ramp / Soak Programmable PID/On-Off Temperature Controller.
Size: 48w x 96h x 110d mm
Libratherm offers Microcontroller-based Ramp/Soak Programmable PID Temperature Controller Model PRC-489 which is designed to improve reliability, accuracy, and control for all temperature control applications. It features Ramp and Soak functions (the capability to control the temperature and its rate of change over a predetermined time span). The single pattern of a total of 16 (ramp/soak) steps can be programmed and stored in the memory. It can also be used as single set point control when the ramp/soak profile control is not desired. The controllers are calibrated for K type thermocouple.
Control Outputs: This PID Pressure Controller PRC-489 offers both switching outputs in the form of SSR driver/Triac (AC SSR) for external SSR or external load contactor and analog output in the form of (4-20) mA or (0-5) volt control signal, which can be used to control heater power through external Thyristor Power Regulator. The analog outputs can be directly connected to Libratherm make single-phase/three-phase SCR based phase angle or zero cross over fired power regulators. Additional one/two relays are also provided for time or temperature-dependent event outputs as per the system requirement. The programmed profile and other parameters are retained in the nonvolatile memory in the event of power failure.
Thermocouple Break Protection: In the case of a thermocouple break, the control can be transferred to manual mode to continue the heating cycle and the user can alter the % of control output. The deviation hold feature assures guaranteed ramp. For quick heating from the ambient temperature, the hold feature is disabled in the very 1st ramp. Front Panel LED indicates the start and end of the cycle, the status of heater output, the status of the heating ramp, soaking, or cooling ramp. The unit of temperature measurement can also be selected as °C or °F as desired.
Auto Tracking Feature: In case of power failure during the normal heating cycle, the temperature is likely to drop. This PID Profile Controller has a special feature to auto-track the heating rate on the resumption of power supply. This is the unique feature of the controller and normally not available in other ordinary controllers.
Master-Slave Control Feature: For larger heating systems requiring more than one controller, the master/slave feature facilitates the user to program one controller as a master and others as a slave. The slave controller will follow the program fed in the master controller. This facility allows uniform heating of the bigger jobs. The master-slave configuration is achieved using the RS485 interface. Out of many controllers, anyone controller can be configured as a master controller and others as slaves. Single Master can control a maximum of 30 slave controllers.
Key Features
- Accepts standard type of thermocouple, RTD, Voltage or Current signal.
- Control output of Relay / TRAIC / DC pulse / (4-20)mA/ (0-5)Volt.
- Servo start from the current process temperature.
- 1 to 16 programmable ramp/soak steps with rate programming facility.
- Master / Slave concept with 1 master and max. 30 slaves.
- Each controller can be configured as master or slave with 1 master and many slaves.
- Can be used as single set point control with online set point change facility.
- Auto Tracking feature to ensure same rate of heating/cooling even after power failure / resumption.
- Deviation hold above and below the set point for assured heating ramp and cooling ramp.
Application:
- Furnace / oven control
- PWHT and SR heat treatment cycle
Technical Specification
Parameters | Description |
---|---|
Input | Cr/Al – K type thermocouple – grounded or ungrounded |
Range | 0 to 1200 °C. |
Resolution | 1 °C/1 °F for thermocouple input. |
(User selectable unit of measurement °C or °F) | |
Indicating Accuracy | +/- 1 °C for Thermocouple throughout the range |
Display | 4 digit 0.25” Red 7-segment display for process variable. |
4 digit 0.25” Green 7-segment display for set value and PID parameters | |
Output Indication | Front Panel LED indications for SSR output. % Control Output and for Alarm status and status of heating, cooling, and soaking |
Control Algorithm | PID or ON/OFF selectable (when specified for switching output). |
Open sensor indication | OPEn flashes on the display and control action are turned off or control can be transferred to manual mode and power can be adjusted through keyboard from 0 to 100%. |
Tuning | Manual tuning of PID values. |
PID Values | Proportional Band (P)= 0.0 to 100.0% of Span, |
Integral (I)= 0.00 to 5.00 resets/minute, | |
Derivative (D) = 0.00 to 10.00miutes, Cycle Time = 2 to 100 seconds. | |
Hysterisis = 0 to 100 °C, Soft start or Ramp time (rt) = 2 to 99 seconds | |
Power Limit (PL) = 0 to 100%. Deviation Hold (dHLd) = 0 to 50oC (0= no auto hold) For 1st preheating ramp, dHLd will not be applicable. | |
Settings | Using the front panel feather touch (tactile) keyboard to set various parameters. |
Control Output | DC pulse to drive external SSR b) Triac(AC switch) 2A @ 250VAC to drive an external relay or contactor coil and c) 4-20mA/0-5VDC to drive external thyristor power regulators. |
Ramp/Soak Steps | 1 to 16 Steps |
Ramp rate (Pr) | 1 °C/hour to 1200oC/hour (for K type t/c) |
Soak Temperature (PL) | Programmable for each step in the full range of the specified input |
Soaking Time (Pd) | 1 minute to 99 Hour. 59Min. |
Program Hold Facility(dHLd) | Manual Hold or Auto Hold (Hold back feature for guaranteed Ramp/Soak facility). Deviation holds effective from 2nd ramp onwards. |
Alarm Output | Relay Output with programmable hysteresis- can be used as High or Low Alarms or End of Profile relay. |
Master / Slave | User programmable as Master or Slave for multi-zone control |
Serial Communication (Optional) | Optically isolated 2 wire RS485 -Modbus RTU protocol – for both master controller and slave controller with programmable slave ID. |
Supply | (90-250)VAC, 50/60 Hz |
Size / Panel Cutout | 48w x 96h x 110d mm. / 45 x 92 mm. +/- 0.5 mm. |
Enclosure | ABS plastic with polycarbonate front graphic. |
Ordering Information
Sr. No. | Specifications | Part No. |
---|---|---|
1.1 | Ramp/Soak controller for K type thermocouple input + SSR control output + Relay control output + High/Low/End of Profile Relay output. | 1706-1 |
1.2 | Ramp/Soak controller for K type thermocouple input + SSR control output + Relay control output + High/Low/End of Profile Relay output + RS-485 interface for Master/Slave control | 1706-2 |
1.3 | Ramp/Soak controller for K type thermocouple input + SSR control output + Relay control output + (4-20)mA control output + High/Low/End of Profile Relay output | 1706-3 |
1.4 | Ramp/Soak controller for K type thermocouple input + SSR control output + Relay control output + (4-20)mA control output + High/Low/End of Profile Relay output + RS-485 interface for Master/Slave control | 1706-4 |
Related products
-
On-Off Temperature Controller – DPC-912
₹3,250 – ₹3,500Select optionsAdd to WishlistAdd to Wishlist -
6 Zone Ramp/Soak Temperature Controller – PRC-8000-6
₹65,100 – ₹71,400Select optionsAdd to WishlistAdd to Wishlist -
Basic On-Off Temperature Controller – DPC-903
₹3,250 – ₹3,500Select optionsAdd to WishlistAdd to Wishlist