Temperature and Humidity Controller for HVAC – DTH-966-AHU
₹11,025 – ₹11,550
Prices are inclusive of Delivery Charges.
DTH-966-AHU: Micro controller based PID/On-Off Temperature & Humidity controller. Two input and two PID/On-OFF control outputs with alarms.
Size (H x W x D): 96 x 96 x 120 mm
Libratherm offers Digital On-Off / PID Temperature and Humidity Controller model AHU-966 for controlling temperature (T) and relative humidity (Rh) for the AHU and other similar HVAC applications. For the proper functioning of the Air Handling unit, it is required to monitor the T and RH of the Air being delivered to the Production or Service Area. The T and RH values are to be compared with the desired set values and based on the error between the process values and set values the operation of the hot/cold water 2 way or 3-way valves/damper Actuators, Heaters, Cooling coils are controlled to maintain the T and Rh in the Airflow processed by the AHU systems.
This Calibrated Temperature and Humidity Meter AHU-966 accepts inputs from a standard T + RH sensor or transmitter. The instrument simultaneously displays the temperature and relative humidity. The PID outputs are available for controlling temperature and %RH in the form of 4-20mA/(0-10)VDC and /or in the form of DC/logic pulses. Common or individual High and Low alarm output in the form of relay contacts for Temperature and humidity can be provided as per the user’s requirement. To meet specific AHU Temperature control applications, the 3-way valve can be operated by 4-20mA/(0-10VDC proportional PID in direct action. To control RH, the DC pulse or 4-20mA/0-10VDC output is available, which can be used to control AC or DC operated solenoid valves or to control the heating using Libratherm make – single or three-phase thyristor control. RS485 serial port is available for interfacing AHU-966 to DDC or PLC or BMS.
Key Features:
- Microcontroller based design.
- Elegant appearance, easy to operate and compact in size.
- Highly accurate and sturdy in operation.
- User programmable settings.
- Dual display for simultaneous indication of T and RH.
- Field proven Algorithm, tested successfully for various AHU / HVAC control applications.
Technical Specification
Parameters | Description |
---|---|
Model | DTH-966-AHU |
Input from T+RH Transmitter | 4-20 mA from T + Rh transmitter |
(both the inputs can be derived from Libratherm make | |
(T + Rh) transmitter model HTX-220/HTX-440 or from any other 3rd party similar transmitter. | |
Input from T+RH Direct Sensor | (0-1)V, (0-3.3)V and/or direct Pt-100 sensor. |
(Like Hygroclip-XD or HTS-220/HTS-440) | |
Range | 0.0 °C to 60.0 °C for temp. (Optional upto 80.0 °C) & 0.0 to 100.0 % for RH. (Programmable Span Hi and Span Lo) |
Resolution | 0.1 °C for Temp. and 0.1 % for RH |
Indicating Accuracy | +/- 0.3 °C for Temp. and + / - 0.5% for RH. |
(Subject to accuracy of the sensor/transmitter used in the system) | |
Display | 4-digit 0.5" Red 7-segment display for Temp. in oC. |
4-digit 0.5" green 7-segment display for RH in %. | |
Front Panel LED indications for Control outputs and alarms. | |
Control Action | PID - User selectable Direct and Reverse action. |
(Direct/Reverse) | (In DIRECT action the control output increases as the process value approaches towards the set value and In REVERSE action the control output decreases as the process value approaches towards the set value) |
Control Output | a) Dual 4-20 mA or 0-10VDC/0-5VDC for T and RH control |
b) Dual DC pulse (0 to 12)VDC - for T and RH (PID + On-Off) | |
Control settings | Set points PID and On-Off hysteresis values for T and Rh are individually programmable through key board. |
Alarm settings | High and Low settable for each T and RH with programmable Hysteresis. |
Alarm Outputs | 2 sets of relay contacts (C1-NO1), (C2-NO2) |
Tuning | Manual tuning of PID values. |
Memory Backup | Retention of PID and Set values in the built in non-volatile memory in case of power failure and automatic re-execution of control on power resumption. |
Serial Interface (Optional feature) | Two wire RS485 on Modbus RTU Protocol for PC/DCS/PLC/BMS interface (in slave mode with user programmable ID). |
Supply | 90-240VAC, 50/60Hz. |
Ordering Information
Sr. No. | Model | Specifications | Part No. |
---|---|---|---|
1.1 | DTH-966 | Input : 2 X 4-20mA, Output : 2 x SSR + 2 x Analog Output + 2 x Relay | 3321-1 |
1.2 | DTH-966 | Input : 2 X 4-20mA, Output : 2 x SSR + 2 x Analog Output + 2 x Relay + RS-485 | 3321-2 |
2.1 | DTH-966 | Input : 0 to 3.3V + Pt-100, Output : 2 x SSR + 2 x Analog Output + 2 x Relay | 3322-1 |
2.2 | DTH-966 | Input : 0 to 3.3V + Pt-100, Output : 2 x SSR + 2 x Analog Output + 2 x Relay + RS-485 | 3322-2 |
Related products
-
Temperature and Humidity Controller with Real Time Data Logging – HTC-3003
₹16,275 – ₹23,625Select optionsAdd to WishlistAdd to Wishlist -
Temperature and Humidity Indicator with WiFi – HTM-3000-I
₹21,525 – ₹22,575Select optionsAdd to WishlistAdd to Wishlist -
Flameproof Temperature and Humidity Transmitter with Display – FTX-3000-TH
₹9,975 – ₹16,800Select optionsAdd to WishlistAdd to Wishlist