Signal Isolator/Repeater Temperature to DC Signal – ISM-12-1-2 (T)
₹3,938
Prices are inclusive of Delivery Charges.
Product Description:
ISM-12-1-2 (T) – Single input & Two outputs operating on 24VDC (18-36)VDC
Please refer the Ordering Information table before placing your order.
Key Features
- Accepts K type thermocouple or RTD (Pt-100) sensors as the inputs and provides optically isolated and proportional V/I analogue output.
- On site calibration facility-using ZERO/SPAN presets.
- Operates on 230VAC/110VAC or 24VDC (18-36)VDC.
- Designed using ultra low drift components for long term stability.
Application
- Interface of low-level signals coming from the sensors or transducers from the plant to DCS, SCADA, PLC or PID process controllers without ground line interferences.
- Signal multiplier – single input and 2 to 4 outputs.
Technical Specification
Parameters | Description |
---|---|
Input | 1) RTD(Pt-100) |
2) Cr/AL – K type thermocouple | |
Range | -50 to 100 °C, 0 to 200 °C and 0 to 400 °C for RTD (Pt-100) |
0 to 400 °C, 0 to 800 °C, 0 to 1200 °C For K Type Thermocouple | |
Output | (4-20) mA, (0-5)VDC, (0-10) VDC |
For current output, RL (max) = 500 Ohms. | |
For voltage output, RL (min) = 100K Ohms. | |
No. of Outputs | Maximum 2 parallel independent outputs can be provided for a single input. Each output can be the same or different. |
Accuracy | Output will be linear to the resistance value of the RTD (Pt-100) and emf/millivolt generated by the thermocouple. |
Calibration | On site calibration facility through ZERO and SPAN presets accessible to the user. |
Isolation | Input and Output are optically isolated for DC inputs and galvanically isolated for the AC inputs. Power supply is also isolated from Input and Output.(3 way isolation) |
Isolation Voltage | Greater than 1 KV. |
Mounting | 35-mm. DIN rail mounting ABS enclosure. |
Supply | AC Supply : 230VAC +/-10%, 50/60Hz or |
DC Supply : 24VDC (18-36)VDC. | |
Size | 22 x75 x 100 |
Ordering Information
Sr. No. | Specifications | Part No. |
---|---|---|
1.1 | Input : Pt-100(-50 to 100) °C, Output : 2 x 4-20mA | 2036-1-1 |
1.2 | Input : Pt-100(-50 to 100) °C Output : 2 x 0-5V | 2036-1-2 |
1.3 | Input : Pt-100(-50 to 100) °C Output : 2 x 0-10V | 2036-1-3 |
1.4 | Input : Pt-100 (0 to 200) °C , Output : 2 x 4-20mA | 2036-1-4 |
1.5 | Input : Pt-100 (0 to 200) °C , Output : 2 x 0-5V | 2036-1-5 |
1.6 | Input : Pt-100 (0 to 200) °C , Output : 2 x 0-10V | 2036-1-6 |
1.7 | Input : Pt-100 (0 to 400) °C , Output : 2 x 4-20mA | 2036-1-7 |
1.8 | Input : Pt-100 (0 to 400) °C , Output : 2 x 0-5V | 2036-1-8 |
1.9 | Input : Pt-100 (0 to 400) °C , Output : 2 x 0-10V | 2036-1-9 |
2.1 | Input : K T/C (0 to 400) °C, Output : 2 x 4-20mA | 2037-1-1 |
2.2 | Input : K T/C (0 to 400) °C Output : 2 x 0-5V | 2037-1-2 |
2.3 | Input : K T/C (0 to 400) °C Output : 2 x 0-10V | 2037-1-3 |
2.4 | Input : K T/C (0 to 800) °C, Output : 2 x 4-20mA | 2037-1-4 |
2.5 | Input : K T/C (0 to 800) °C Output : 2 x 0-5V | 2037-1-5 |
2.6 | Input : K T/C (0 to 800) °C Output : 2 x 0-10V | 2037-1-6 |
2.7 | Input : K T/C (0 to 1200) °C, Output :2 x 4-20mA | 2037-1-7 |
2.8 | Input : K T/C (0 to 1200) °C Output : 2 x 0-5V | 2037-1-8 |
2.9 | Input : K T/C (0 to 1200) °C Output : 2 x 0-10V | 2037-1-9 |
Related products
-
Signal Isolator/Repeater AC to DC Signal – ISM-10-1-2 (H)
₹3,938Select optionsAdd to WishlistAdd to Wishlist -
Signal Isolator DC to DC Signal – ISM-12-1-1 (L)
₹3,413Select optionsAdd to WishlistAdd to Wishlist -
Signal Isolator/Repeater Frequency to DC Signal – ISM-12-1-2 (F)
₹3,938Select optionsAdd to WishlistAdd to Wishlist